Crack & joint filling Chased · filled · ground flush

Coatings don't hide cracks. THEY REVEAL THEM.

Concrete moves. It shrinks, swells, settles and reacts to every Erie freeze and thaw. Every crack and joint gets the right repair before anything goes over it, or it comes right back through.

Same floor, same cracks, two ways
A glossy gray coated floor with no cracks showing
The concrete slab under the coating: cracks chased open and filled
Coated over the cracksCoated overChased, filled, ground flushFixed first
Day one2 yrs4 yrs8 years
Day oneBoth sides look perfect. That's the trap. Slide the years.

A demo on a real 814 coated floor, with the crack lines traced from a real slab we repaired. Drag the divider to compare. A coating is a thin skin bonded to the slab: when the crack under it moves, the coating cracks right along the same line, then the edges lift and chip. Chased, filled and ground flush first, the crack has nothing to push through.

There's no universal crack filler. There's the right repair for that crack.

Chased with a crack saw Matched to the floor going over it Ground flush before anything goes over it
Polish it or coat it?

Not all cracks are made the same.

The biggest question is what's going over it. Polishing gets one filler, coatings and grind and seal get another, and missing concrete gets built back.

Two control joints crossing in a concrete floor, filled with semi-rigid filler dyed black, before shaving and polishing
01 · If it's getting polished

RS-88 in every joint and crack

Semi-rigid polyurea

Any time we polish, this goes in. RS-88 from Metzger/McGuire is made for control joints in polished concrete: firm enough to grind, with a little flex so it moves with the joint instead of cracking out. It can be tinted almost any color. We lay it in a little proud, shave it off smooth after 10 to 20 minutes, then grind and polish it right along with the concrete so it matches the floor. We use it for cracks on polished floors too.

A cracked concrete floor with every crack filled with polyurea and sand, ready to be ground flush before a metallic epoxy floor. The little dots along the cracks are drips of filler; they come off when the floor is ground.
02 · If it's getting coated or sealed

Our polyurea and sand paste

About 3,500 PSI in 10 minutes

For cracks and spalls under an epoxy or flake floor, and under a grind and seal. We mix polyurea with sand into a thick paste, a little slurry, and work it into every crack and broken-out spot. About 10 minutes later it's hard, around 3,500 PSI. We grind it flush and coat right over it. It fills them for good and saves a day of waiting on slower patches.

A polishable cement overlay freshly poured smooth in a broken-out storefront doorway, taped off along the entrance
03 · When concrete is missing

Building it back up

Cementitious overlay

When a whole section has broken out, like this storefront doorway, it gets built back with a cement overlay that bonds like concrete. Once it's set, it's ground flush and the floor goes over it, or it's polished right along with the rest, like nothing was ever missing. See overlays.

A long broken-out strip in a warehouse floor built back with fresh cement repair, coned off between the racks at Curtze in ErieCurtze, Erie: built back between the racks
Control joints are not cracks

A joint is a crack the builder planned.

Control joints are saw cuts made on purpose, so the slab cracks where it's told to instead of across the middle of the room. Left open, they collect dirt, catch wheels and break the look of a finished floor. Filled with the wrong product, they crack, sink or pull out.

On a polished floor, every joint gets RS-88: clean and vacuum it, set a backer rod where the depth calls for it, and lay the filler in a little proud. After 10 to 20 minutes it's shaved off smooth, then ground and polished with the floor. Tinted to blend in or dyed to stand out as a clean line, your choice.

Under a coating, we can fill control joints with our polyurea and sand paste once the slab has been there long enough to be done moving. It's not something we usually recommend, since a joint is where the slab is meant to move, but we do it, and we'll talk through it with you first.

Control joints across a room filled with semi-rigid filler dyed black, ready to be shaved off and polished with the floorDyed black, ready to shave and polish
How we do it

The part nobody photographs.

Crack repair isn't the part that shows up in a picture of a finished floor, so some contractors rush it, skim over it, or skip it and hope the coating hides it. It doesn't. Three months later, every crack left under a coating is a weak line in it.

We come from a background in masonry and concrete restoration. We were reading slabs before we were coating them, and we look at yours the same way.

Where it goes

Under every floor we put down.

Crack and joint repair is part of every coating, polished floor and grind and seal we install across Erie and Northwest PA, and we do it on its own for slabs that need it.

A long open room with a dark polished concrete floor, joints filled and polished flushPolished floor, joints filled flush
A flake-coated garage floor with its control joints and trench drain detailed cleanFlake garage, joints detailed
Our crew filling a control joint with polyurea from a two-part pump cart before a grind and sealFilling joints before a grind and seal
A large warehouse floor finished with grind and seal, joints and cracks filled before sealingWarehouse, grind and seal
Warranty

7 years on our crack repairs. If a crack we filled opens back up through your floor, we come back and fix it. Concrete keeps moving, so new cracks that form after we leave, and slabs that are still settling, aren't covered.

Straight talk

What it is, and what it isn't.

The right call when…

  • You're planning a polished floor and the joints need filling before the diamonds start
  • Your slab has cracks that have moved, and a coating is going over it
  • A floor you had before failed along the cracks or joints
  • It's a commercial or industrial job where the prep has to match the finish

Not what you need when…

  • The slab is still sinking or heaving. A filler can't hold a slab that's moving that much; that's a structural fix first, and we'll tell you so.
  • You want cracks to vanish on bare, uncoated concrete. A filled crack still shows unless something goes over it, like a flake floor or polishing.
  • You're hoping the coating will cover it. That's the mistake this page is about.
Need a slab assessment?

We'll walk your concrete.

Every job starts on site. We'll walk the slab, find what needs fixing, spec the right repair for each crack and joint, and give you an accurate number before any work begins. No ballpark from a photo.

Phone(814) 812-3118
Emailoffice@814epoxyandmore.com
AreaErie, PA and surrounding counties

We only use this to get back to you about your floor. Privacy